The primary function of this User‘s Guide is to help you, the maintenance professional, with the proper selection and use of Loctite® products. A wide variety of preventative maintenance, as well as repair techniques, are explained in step-by-step detail. Consider this a supplemental service manual for every piece of equipment in your plant. Our goal is to make it easier for you to use our products to your benefit for faster repair times, reduced downtime, and extended equipment life. Additional information on these products, as well as others, is available by contacting your local Loctite adhesives and sealants representative at the telephone number listed on the back cover of this guide.

THREADLOCKING

THREAD SEALING

THRU HOLES (BOLTS AND NUTS) PAGE 4

BLIND HOLES 4,5

STUDS 5

HIGH STRENGTH DISASSEMBLY 5

PRE-ASSEMBLED FASTENERS 6

ADJUSTMENT SCREWS 6

STRIPPED THREAD REPAIR 7

HEAT SEIZURE PREVENTION 8

ANTI-SEIZE/THREADLOCKER QUICK SELECTOR 8 WHY USE PRIMERS? 8 STANDARD FITTINGS 9 PIPE UNIONS 9 COMPRESSION FITTINGS 10 FLARED SWAGED FITTINGS 10 HOSE ENDS 11 THREAD SEALING QUICK SELECTOR 11

LOCTITE MAINTENANCE PRODUCTS

CONTENTS

PUNCTURE SEALING POROSITY SEALINGS

FORM-IN-PLACE GASKETING

GASKET DRESSING FORM-IN-PLACE SILICONES

KEYED ASSEMBLIES

SHAFT MOUNTED ASSEMBLIES

HOUSED COMPONENTS

BONDING

RUSTPROOFING CLEANING TROUBLESHOOTING ORDERING MSDS/TECHNICAL INFO

TANKS, VESSELS, ETC. 12 EXISTING WELDS 13 NEW WELDS 13 CASTINGS 13 SEALING CAST RIGID FLANGES 14 GASKETING QUICK SELECTOR 14 SEALED FLANGES 15 STAMPED FLANGES/LARGE GAPS 16 SILICONE QUICK SELECTOR 17 LIGHT DUTY/HIGH REPLACEMENT 18 HEAVY DUTY 19 REPAIRING BADLY WALLOWED KEYWAYS 20 REPAIRING BADLY WORN SHAFTS 21 SLIP FIT – LIGHT DUTY 22 SLIP FIT – HEAVY DUTY 23 PRESS FIT 24 SLIP FIT – LIGHT DUTY 25 SLIP FIT – HEAVY DUTY 26 REPAIRING BADLY WORN HOUSING 27 COMPONENT CENTERING 28 SEALING/RETAINING METALLIC SEALS 29 RETAINING COMPOUNDS QUICK SELECTOR 30 GUIDE – GENERAL INFO 31 PROPER JOINT DESIGN 32 ADHESIVE QUICK SELECTOR 33 GUIDE – GENERAL INFO 34 PARTS CLEANING/HAND CLEANING 35 CHECKLIST 36 PRODUCT LISTING 37 BACK COVER

LOCTITE MAINTENANCE PRODUCTS

THREADLOCKING

1.

Clean all threads (bolt and nut) with Loctite® ODC-Free Cleaner & Degreaser.

2.

If necessary, spray all threads with Loctite® 7649 Primer N. Allow to dry.

3.

Select the proper strength Loctite Threadlocker product.

4.

Insert bolt into thru hole assembly.

5.

Apply several drops of Threadlocker onto bolt at targeted tightened nut engagement area.

6.

Assemble and tighten nut as usual.

1.

Clean all threads (bolt and hole) with Loctite® ODC-Free Cleaner & Degreaser.

2.

If necessary, spray (bolt and hole) with 7649 Primer N. Allow 30 seconds to dry.

3.

Select the proper strength Threadlocking product.

4.

Squirt several drops down the sides of the female threads.

5.

Apply several drops to bolt.

6.

Tighten as usual. Note: Using Loctite® Threadlockers will virtually eliminate stripped

threads in aluminum or magnesium housings caused by galvanic corrosion.

LOCTITE MAINTENANCE PRODUCTS

THREADLOCKING

1.

Clean all threads (bolt and hole) with Loctite® ODC-Free Cleaner & Degreaser.

2.

If necessary, spray all threads with 7649 Primer N. Allow to dry.

3.

Squirt several drops of Loctite® 262 Threadlocker down the sides of the

female threads.

Note: Use 277* Threadlocker if stud is over 1" diameter.

4.

Apply several drops of 262 Threadlocker onto stud threads.

5.

Install studs.

6.

Position cover, head, etc.

7.

Apply drops of Loctite 242® (243*) Threadlocker onto exposed threads.

8.

Tighten nuts as required.

* Worldwide or Application-Specific Alternative

Localized Heating Methods

1.

Apply localized heat to nut or stud (450°F for 5 minutes).

2.

Disassemble while HOT.

Note: Use standard hand tools for disassembly of low and medium strength Threadlockers.

LOCTITE MAINTENANCE PRODUCTS

THREADLOCKING

1.

Clean bolts and nuts with Loctite® ODC-Free Cleaner & Degreaser.

2.

Assemble components.

3.

Tighten nuts.

4.

Apply drops of Loctite® 290 Threadlocker at the nut and bolt juncture.

5.

Avoid touching bottle tip to metal. Note: For preventive maintenance on existing equipment:

RETIGHTEN nuts and apply Loctite® 290 Threadlocker at the nut and bolt juncture.

1.

Adjust screw to proper setting.

2.

Apply drops of Loctite® 290 Threadlocker at screw and body juncture.

3.

Avoid touching bottle tip to metal.

Note: • If re-adjustment is difficult, apply heat to screw with soldering gun (450°F).

• Loctite® 222MS Threadlocker is a weaker version of Loctite® 290 Threadlocker.

LOCTITE MAINTENANCE PRODUCTS

THREADLOCKING

Release Agent

Stripped Threads

FORM-A­THREAD®

1/2 Fill Only

Tape Cleaned Bolt

Threadlocker

Release Agent

FORM-A­THREAD®

Tape

Cover

Plate

New Threads

Step 3

Step 1 Step 2

STANDARD THREAD REPAIR

1.

Follow instructions on Loctite® FORM-A-THREAD® package.

2.

If cover plate is used for bolt alignment:

(a)

Apply release agent to mating faces around repair area.

(b)

Use “waxed” paper or similar film between faces.

3.

A “jiggling/twisting” motion when initially inserting bolt improves thread-

conformation.

Note: NOT intended for engine stud repair.

SMALL HOLE/FINE THREAD REPAIR

OPTION 1. Drill out damaged hole to oversize then follow STANDARD THREAD REPAIR.

OPTION 2. Apply FORM-A-THREAD® to screw and insert into damage hole. Clamp in place while product cures.

STUD INSTALLATION — PERMANENT (LIGHT DUTY)

1.

Use stud or cut “all thread” to desired length.

2.

Do NOT apply release agent to stud.

3.

Proceed as STANDARD THREAD REPAIR.

4.

Allow 30 minutes to cure.

5.

Assemble as required.

LOCTITE MAINTENANCE PRODUCTS

THREADLOCKING

LOCTITE® ANTI-SEIZE QUICK SELECTOR

Color Max Temp. Product Size

C5-A® Copper 1800°F 51007 51003 1 lb. Brush Top 12 oz. aerosol

Silver Grade 1600°F 76764 76759 1 lb. Brush Top 12 oz. aerosol

Nickel 2400°F 77164 51286 1 lb. Brush Top 12 oz. aerosol

Anti-Seize compounds protect mated metal parts against friction, galling and corrosion. Anti-Seize also reduces wrench torque to facilitate assembly and disassembly of threaded connections.

LOCTITE® THREADLOCKER QUICK SELECTOR Use Strength Product Color Small Screws Low 222MS Purple Nuts & Bolts Medium 242® (243*) Blue Pre-Assembled Medium 290 Green Nuts & Bolts High 262 Red Studs (up to 1") High 262 Red Studs (over 1") High 277 Red

WHY USE A PRIMER?

1.

Primers activate inactive surfaces.

2.

Primers speed cure times for faster return to service.

3.

Primers speed curing through larger gaps and deep threads.

4.

Primers substantially speed cure times on cold parts.

5.

Primers act as cleaning agents.

Active surfaces (Primer optional): Brass, copper, bronze, iron, soft steel, nickel. Inactive surfaces (Primer required): Aluminum, stainless steel, magnesium, zinc, black oxide, cadmium, titanium, others.

*Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

THREAD SEALING

1.

Clean parts of contamination. If necessary, spray Loctite® 7649 Primer N onto threaded parts (male and female). Allow to dry. Note: Primer is not required for brass parts.

2.

Apply a band of PST® Pipe Sealant to male threads starting one to two threads from end of pipe.

3.

Assemble parts snugly. Do not overtighten.

4.

If initial pressure exceeds 1000 psi*, wait 30 minutes before pressurizing.

Note:



For stainless steel components, use PST® Pipe Sealant 567.



For general purpose thread sealing, use PST® Pipe Sealant 565.



For fine filtration systems requiring zero contamination, use

Hydraulic/Pneumatic Sealant 545.



For easier disassembly or large diameter fittings, use Thread Sealant 564.



If sealing chemicals or strong acids/bases, refer to Fluid

Compatibility Chart (LT-836).



Do not use on oxygen or strong oxidizers (chlorine).



Do not use on PVC or ABS pipe.

*Depending on conditions

PST® Band PST® Band PST® Band

1.

Disassemble and if necessary, spray all components with Loctite® 7649 Primer N. Allow to dry.

2.

Apply a thin coating of PST® Pipe Sealant to union face.

3.

Apply a band of PST® Pipe Sealant to male threads.

4.

Assemble parts snugly.

LOCTITE MAINTENANCE PRODUCTS

THREAD SEALING

1.

Slide fitting nut and ferrule back approximately 3/4" from end of tubing.

2.

If necessary, spray the entire assembly with Loctite® 7649 Primer N. Allow to dry. Note: Primer is not required for brass parts.

3.

Apply a thin coating of PST® Pipe Sealant to tubing where ferrule will be located.

4.

Slide ferrule forward over PST® Pipe Sealant coated tubing, then apply a thin bead of PST® Pipe Sealant coating to ferrule.

5.

Slide ferrule forward over PST® coated tubing.

6.

Apply a small band of PST® Pipe Sealant to male threads.

7.

Assemble and tighten normally. Note: Do not use on plastic fittings or tubing.

PST® Band

1.

Disassemble and if necessary, spray all components with Loctite® 7649 Primer N. Allow to dry.

2.

Apply a thin coating of PST® Pipe Sealant to fitting face.

3.

Apply a band of PST® Pipe Sealant to male threads.

4.

Assemble parts snugly.

LOCTITE MAINTENANCE PRODUCTS

THREAD SEALING

1.

If necessary, spray adapter threads with Loctite® 7649 Primer N. Allow to dry.

2.

Insert barbed hose stem into hose I.D. with slight twisting motion.

3.

Install appropriate hose clamp.

4.

Apply a band of PST® Pipe Sealant to male hose stem threads upon

installation or adding accessory device. Tighten snugly. Note: PST® may attack synthetic rubber tubing.

THREAD SEALING QUICK SELECTOR (TAPERED THREADS)

Application Product Primer Instant Seal Max. Pressure Max. Steam Temp. Range

Stainless Steel and All Other Metal Fittings PST® Pipe Sealant 567 N 500 PSI 10000 PSI (24 Hours) 135 PSI -65° to +400°F

Most Metal Fittings Except Stainless Steel PST® Pipe Sealant 565 N 500 PSI 10000 PSI (24 Hours) -65° to +300°F

High Filtration/ Zero Contamina­tion Systems Hydraulic/ Pneumatic Sealant 545 T 500 PSI 10000 PSI (10 Mins.) (24 Hours) -65° to +300°F

Stainless Steel Thread Sealant N 500 PSI 10000 PSI -65° to

and All Other Metal Fittings 564 (24 Hours) +300°F

(lower strength)

DO NOT USE THESE PRODUCTS ON OXYGEN OR STRONG OXIDIZERS.

FLUID COMPATIBILITY QUESTIONS?

1.

Refer to Fluid Compatibility Chart – LT-836.

2.

Contact your local Industrial Distributor.

3.

Call Loctite Technical Information. See back cover for the Loctite Technical Information number in your area.

LOCTITE MAINTENANCE PRODUCTS

PUNCTURE SEALING

1.

IMPORTANT! TAKE PROPER SAFETY PRECAUTIONS IF WORKING WITH FLAMMABLE LIQUID TANKS. AVOID USE WITH COMPRESSIBLE GASSES.

2.

Clean the repair area with Loctite® ODC-Free Cleaner & Degreaser.

3.

Roughen a 1"- 2" radius around hole with emery cloth. Clean again.

4.

Prepare a metal disc patch slightly larger than hole.

5.

Mix Loctite® Fixmaster® Fast Cure Epoxy (A and B) per directions.

6.

Apply a thin layer of Fast Cure Epoxy to roughened area.

7.

Immediately position disc patch over hole.

8.

Apply a cover layer of Fast Cure Epoxy over disc patch and Epoxy layer 1.

9.

Allow to cure before service use:

a.

Liquid storage — 1 hour.

b.

Low pressure (under 150 PSI) — 1 hour.

c.

High Pressure — Not Recommended over 150 PSI.

10.

Paint as required.

SEALING CRACKS

1.

Drill termination holes to prevent further cracking.

2.

Follow directions above. Modify as needed.

SEALING PINHOLES

1. Follow directions above. No disc patch needed.

LOCTITE MAINTENANCE PRODUCTS

POROSITY SEALINGS

Weld Sealant (AA or 290)

Weld Bead

Tank Wall

Weld Porosity

1.

IMPORTANT! TAKE PROPER SAFETY PRECAUTIONS IF WORKING WITH FLAMMABLE LIQUID TANKS. AVOID USE WITH COMPRESSIBLE GASSES.

2.

Wire brush to remove paint, rust, etc. from repair area.

3.

Clean repair area with Loctite® ODC-Free Cleaner & Degreaser.

4.

Apply localized heat to bring repair area to approx. 250°F.

5.

Allow repair area to cool to approx. 185°F.

6.

Brush or spray sealant on repair area.

Note:



Steel — Use Loctite® AA Weld Sealant at 185°F.



Aluminum/stainless — Use Loctite® 290 Threadlocker at 120°F. Note:



Not recommended for “blowholes”



Maximum porosity sealed — .005"

7.

Allow to cure for 30 minutes (High Pressure above 150 PSI — 1 hour)

8.

Clean with Loctite® ODC-Free Cleaner & Degreaser to remove excess sealant. Do not grind.

9.

Paint as required. Note: Casting repair uses same procedure.

SEALING NEW WELDS — PREVENTATIVE MAINTENANCE

1.

Remove all slag and scale while hot.

2.

Apply sealant when weld is 185°F and falling.

3.

Follow information above.

LOCTITE MAINTENANCE PRODUCTS

FORM-IN-PLACE GASKETING

Flat Flange Raised Flange

1.

Remove old gasketing material and other heavy contaminants with Loctite®

CHISEL® Gasket Remover. Use mechanical removal technique if required. Note: Avoid grinding.

2.

Clean both flanges with Loctite® ODC-Free Cleaner & Degreaser.

3.

Spray Loctite® 7649 Primer N on only one surface. Allow 1-2 minutes to dry.

4.

Apply a continuous bead of GASKET ELIMINATOR® to the other surface. Note: Circle all bolt holes with sealant, if appropriate.

5.

Mate Parts. Assemble and tighten as required. Note: Immediate assembly not required; however avoid delays over 45 minutes.

6.

Allow to cure:

a.

No pressure – immediate service

b.

Low pressure (up to 500 PSI) – 30 to 45 minutes

c.

High pressure (500 to 2500 PSI) – 4 hours

d.

Extreme high pressure (2500 to 5000 PSI) – 24 hours

LOCTITE® GASKETING QUICK SELECTOR Gap Temp. Use Product Fill Range

General MASTER GASKET® Kit .050" -65° to 300°F General GASKET ELIMINATOR® 518 .050" -65° to 300°F General GASKET ELIMINATOR® 515 .050" -65° to 300°F Hi-Temp GASKET ELIMINATOR® 510 .020" -65° to 400°F

LOCTITE MAINTENANCE PRODUCTS

GASKET DRESSING

1.

Remove old gasketing material and other heavy contaminants with Loctite®

CHISEL® Gasket Remover. Use mechanical removal technique if required. Note: Avoid grinding.

2.

Clean both flanges with Loctite® ODC-Free Cleaner & Degreaser.

3.

Spray Loctite® 7649 Primer N on both flange faces and both sides of the precut gasket. Allow 1-2 minutes to dry.

4.

Smear GASKET ELIMINATOR® to both sides of precut gasket with a clean applicator.

5.

Place coated gasket on flange surface and assemble parts immediately.

Note:



If cover bolts into blind holes (as above), apply 242®(243*)

Threadlocker into hole and on threads. Tighten normally.



If through bolt assembly, apply 242®(243*) Threadlocker to

bolt threads.

6. Tighten normally.

* Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

FORM-IN-PLACE GASKETING

1.

Remove old gasketing material and other heavy contaminants with Loctite® CHISEL® Gasket Remover.

2.

Clean both flanges with Loctite® ODC-Free Cleaner & Degreaser.

3.

Apply a continuous bead of Loctite® Instant Gasket or High Performance Silicones to sealing surface. Circle all bolt holes.

Note:



Use proper bead diameter to seal flange width and depth.



Minimize excessive material “squeeze in”.

4.

Assemble within 10 minutes by pressing together. Tighten as required.

5.

Clean up any excess or squeeze out.

6.

Cure times will vary with temperature, humidity, and gap. Typical full cure time is 24 hours.

INSTANT GASKET* 587 BLUE

Color Black Blue Viscosity cP Paste Paste Gap Fill 0.250” 0.250” Cure Method Moisture/Oxime Moisture/Oxime Cure Speed

Tack Free 30 Minutes 30 Minutes Full Cure 24 Hours 24 Hours Sevice Temp. Range Intermitent -75° to 500°F -75° to 500°F -59° to 260°C -59° to 260°C *Instant Gasket provides a low pressure instant seal (100 psi at zero gap).

LOCTITE MAINTENANCE PRODUCTS

FORM-IN-PLACE GASKETING

LOCTITE® HIGH PERFORMANCE SILICONES QUICK SELECTOR

Product Use Gap Fill Temperature Range1

587 Blue General .250 -75° to 450°F

598 Black General .250 -75° to 450°F

5699 Grey General .125 -75° to 450°F

5920 Copper Hi-Temp .250 -75° to 600°F

1.

Continuous service. Intermittent temperature higher than established range.

2.

Exceeds import manufacturers performance requirements.

Note: Silicones used at extreme high temperatures can seal but lose various properties.

REASONS TO USE HIGH PERFORMANCE SILICONES INSTEAD OF STANDARD RTV SILICONES



LOCTITE® HIGH PERFORMANCE SILICONES WILL NOT CORRODE STEEL OR ALUMINUM. Standard RTV acetoxy silicones (vinegar smell) should not be used to seal closed systems (gear boxes, electrical boxes, etc.). Acetic acid will corrode internal parts (bearings, contacts, etc.).



LOCTITE® HIGH PERFORMANCE SILICONES ARE 8 TIMES MORE OIL RESISTANT THAN STANDARD RTV SILICONES. Standard RTV silicones should not be used to seal ”Hot Oil” systems (oil pan, etc.). They swell and lose sealing ability.

REASONS TO USE GASKET ELIMINATOR® INSTEAD OF STANDARD RTV SILICONES



LOCTITE® GASKET ELIMINATOR® IS RESISTANT TO GASOLINE AND FUEL OILS. Silicones should not be used to seal fuel systems. They swell and lose sealing ability.



LOCTITE® GASKET ELIMINATOR® RESISTS “BLOW-OUT”. Silicones are not recommended for high pressure applications.

LOCTITE MAINTENANCE PRODUCTS

STRENGTHEN KEYED ASSEMBLIES

ASSEMBLY

1.

Clean all parts with Loctite® ODC-Free Cleaner & Degreaser.

2.

If necessary, spray all parts (I.D. and O.D.) with Loctite® 7649 Primer N.

3.

Apply Loctite® QUICK METAL® 660 coating into keyway and on key.

4.

Apply dab(s) of QUICK METAL® 660 onto shaft opposite keyway or evenly spaced around shaft.

5.

Assemble parts. Wipe off excess.

6.

Apply QUICK METAL® 660 dab to set screw.

7.

Tighten set screw.

8.

Allow 5-10 minutes prior to service.

Note:



QUICK METAL® 660 is NOT recommended for radial gaps

exceeding .010" on shaft or keyway.



See BADLY WALLOWED KEYWAY for procedure page 20.

DISASSEMBLY

1.

Tap component and key with hammer.

2.

Pull as usual.

* Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

STRENGTHEN KEYED ASSEMBLIES

ASSEMBLY

1.

Clean all parts with Loctite® ODC-Free Cleaner & Degreaser.

2.

Apply a QUICK METAL® 660 coating around shaft, into keyway, and on key.

3.

Assemble parts. Wipe off excess.

4.

Apply a QUICK METAL® 660 dab to screw.

5.

Tighten set screw.

6.

Allow 30 minutes prior to service.

Note:



If gap exceeds .005", use Loctite® 7649 Primer N on appropriate area (shaft or keyway).



QUICK METAL® 660 is NOT recommended for radial gaps

exceeding .010" on shaft or keyway.



See BADLY WALLOWED KEYWAY for procedure page 20.

DISASSEMBLY

1.

Tap component and key with hammer.

2.

If necessary, apply localized heat (450° for five minutes).

3.

Pull while hot.

* Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

STRENGTHEN KEY ASSEMBLIES

1.

Determine the gap width on each side of key.

2.

Select and trim appropriate shim stock.

3.

Clean all parts with Loctite® ODC-Free Cleaner & Degreaser.

4.

If necessary, spray all parts with Loctite® 7649 Primer N. Allow to dry.

5.

Apply a Loctite® QUICK METAL® 660 coating into keyway

6.

Install shims.

7.

Assemble as required using QUICK METAL® 660.

8.

Allow 30-60 minute cure time.

Note:



Minimize “gap fill” using shim stock.



QUICK METAL® 660 is NOT recommended for lateral gaps

exceeding .010".



Higher strengths are obtained by NOT using Primer N with small (.002"-.004") gap, and allowing longer cure (4-24 hours).

EMERGENCY REPAIR ONLY!

Due to the nature of the damage, this should be considered a temporary repair until the unit can be replaced.

LOCTITE MAINTENANCE PRODUCTS

SHAFT MOUNTED COMPONENTS

1.

Determine a minimum radial gap.

2.

Select and trim appropriate sleeve to allow component slip fit.

3.

Roughen sleeve O.D. with emery cloth.

4.

Clean all parts with Loctite® ODC-Free Cleaner & Degreaser.

5.

Apply a Loctite® RC™ 680 or Loctite® QUICK METAL® 660 coating around the shaft.

6.

Install sleeve.

7.

Apply a coating of Loctite® QUICK METAL® 660 to sleeve O.D.

8.

Install component as required onto sleeved shaft.

9.

Allow 30-60 minute cure.

Note:



Minimize gap fill using shim stock or sleeve material.



QUICK METAL® 660 is NOT recommended for radial gaps

exceeding .010".



Higher strengths are obtained by NOT using Primer N with small

(.002"-.004") gap, and allowing longer cure (4-24 hours).

EMERGENCY REPAIR ONLY!

Due to the nature of the damage, this should be considered a temporary repair until the unit can be replaced.

LOCTITE MAINTENANCE PRODUCTS

SHAFT MOUNTED COMPONENTS

Bearing

QUICK METAL® 660

1.

Machine shaft to .002" radial slip fit with 50-80 rms finish (second cut).

2.

Clean all parts with Loctite® ODC-Free Cleaner & Degreaser.

3.

Spray all parts (I.D. and O.D.) with Loctite® 7649 Primer N.

4.

Apply Loctite® QUICK METAL® 660 dabs around shaft at engagement area.

5.

Assemble parts. Do not rotate.

6.

Wipe off excess.

7.

Allow ten minutes prior to service.

WORN SHAFT

Follow directions above except:

1.

Determine radial gap.

2.

If radial gap exceeds .005", Loctite® 7649 Primer N must be used.

3.

Take steps to maintain concentricity with large gaps.

4.

Larger gaps require longer cure times (30-60 minutes).

5.

Loctite® QUICK METAL® 660 is NOT recommended for radial gaps exceeding .010".

6.

See procedure for BADLY WORN SHAFT page 21.

Note: Loctite® QUICK METAL® 660 is very fast fixturing (30 seconds or less) with Loctite® 7649 Primer N.

LOCTITE MAINTENANCE PRODUCTS

SHAFT MOUNTED COMPONENTS

1.

Machine shaft to .002" radial slip fit with 50-80 rms finish (second cut).

2.

Clean all parts with Loctite® ODC-Free Cleaner & Degreaser.

3.

Do NOT use Loctite® 7649 Primer N.

4.

Apply a Loctite® QUICK METAL® 660 coating around shaft and engagement area.

5.

Assemble parts with rotating motion.

6.

Wipe off excess.

7.

Allow 2 hours prior to service.

WORN SHAFT

Follow directions above except:

1.

Determine radial gap.

2.

If radial gap exceeds .005", Loctite® 7649 Primer N must be used.

3.

Take steps to maintain concentricity with large gaps.

4.

Larger gaps require longer cure times (30-60 minutes).

5.

QUICK METAL® 660 is NOT recommended for radial gaps exceeding .010".

6.

See procedure for BADLY WORN SHAFT page 21.

MAXIMUM STRENGTH

1.

Same as above, except use Loctite® RC™ 680 with Loctite® 7471 Primer T or no primer.

2.

Allow 4-24 hours to cure.

MAXIMUM TEMPERATURE (400°F continuous)

1. Same as above, except use Loctite® RC™ 620 with Loctite® 7471 Primer T.

DISASSEMBLY

1.

Pull as usual.

2.

If necessary, apply localized heat (450°F for 5 minutes). Pull while hot.

LOCTITE MAINTENANCE PRODUCTS

SHAFT MOUNTED COMPONENTS

Bearing

RC™ 609 (603*)

STANDARD

1.

Clean shaft O.D. and Component I.D.

2.

Apply a bead of Loctite® RC™ 609 (603*) to circumference of shaft at leading edge of insertion or leading area of engagement.

Note:



Retaining compound will always be squeezed to the outside when applied to shaft.



Do NOT use with Loctite® Anti-Seize or similar product.

3.

Press as usual. Wipe off excess.

4.

No cure time required.

Note: RC™ 609 (603*) is used due to low viscosity and

wetting properties.

TANDEM MOUNT

1.

Apply retaining compound to bore of inside component.

2.

Continue assembly as above.

* Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

HOUSED COMPONENTS

1.

Select component to fit shaft.

2.

Machine to reduce component O.D. or increase housing I.D. to permit approximate .002" - .004" diametral slip fit.

3.

Clean all parts with Loctite® ODC-Free Cleaner & Degreaser and spray with Loctite® 7649 Primer N.

4.

Apply several Loctite® QUICK METAL® 660 dabs to component O.D.

5.

Install component. Do not rotate.

6.

Wipe off excess.

7.

Allow five minutes prior to service.

WORN

Procedures identical to original slip fit, except:

1.

Determine the maximum radial gap.

2.

If the maximum gap exceeds .005", Loctite® 7649 Primer N must be used.

3.

Take steps to maintain concentricity on large gaps.

4.

Large gaps require longer cure times (30-60 minutes).

5.

QUICK METAL® 660 is NOT recommended for radial gaps exceeding .010".

6.

See procedure for BADLY WORN HOUSING page 27.

LOCTITE MAINTENANCE PRODUCTS

HOUSED COMPONENTS

1.

Select component to fit shaft.

2.

Machine to reduce component O.D. or housing I.D. to permit approximate .002" - .004" diametral slip fit.

3.

Clean all parts with Loctite® ODC-Free Cleaner & Degreaser.

4.

Do NOT use Primer N.

5.

Apply a Loctite® QUICK METAL® 660 coating to component O.D.

6.

Install component with twisting motion.

7.

Wipe off excess.

8.

Allow 2 hours prior to service.

WORN

Procedures are identical to original slip fit, except:

1.

Determine the maximum radial gap.

2.

If the maximum radial gap exceeds .005", then Loctite® 7649 Primer N must be used.

3.

Take steps to maintain concentricity on large gaps.

4.

Large gaps require longer cure times (30-60 minutes).

5.

QUICK METAL® 660 is NOT recommended for radial gaps exceeding .010".

6.

See procedure for BADLY WORN HOUSING page 27.

DISASSEMBLY

1.

Pull as usual.

2.

If necessary, apply localized heat (450° F for five minutes).

3.

Pull while hot.

LOCTITE MAINTENANCE PRODUCTS

HOUSED COMPONENTS

1.

Roughen housing I.D. with emery cloth.

2.

Clean the housing I.D. with Loctite® ODC-Free Cleaner & Degreaser.

3.

Clean the component O.D. and apply Loctite® FORM-A-THREAD® release agent. Allow to dry.

4.

Prepare (mix) Loctite® FORM-A-THREAD®.

5.

Apply a light coating of Loctite® FORM-A-THREAD® to component O.D.

6.

Position the component in housing. Maintain concentricity.

7.

Pack Loctite® FORM-A-THREAD® into gaps and voids.

8.

Wipe off excess.

9.

Allow to cure 30 minutes.

10.

Pull component.

11.

Clean the release compound from component O.D.

12.

Roughen the housing I.D. and clean thoroughly.

13.

Assemble with Loctite® QUICK METAL® 660 as required.

14.

Recommended for light duty service.

EMERGENCY REPAIR ONLY!

Due to the nature of the damage, this should be considered a temporary repair until the unit can be replaced.

LOCTITE MAINTENANCE PRODUCTS

HOUSED COMPONENTS

Shim

1.

Position the component in bore.

2.

Select three equilateral mounting points.

3.

Determine the radial gap at those points.

4.

Select appropriate shim stock.

5.

Cut three pieces approx. 1/8" wide to fit bore depth.

6.

Bond the shims to bore at mounting points using Loctite® Black Max® 380 (480*).

7.

Assemble per instructions page 26.

EXCESSIVE / UNEVEN WEAR

1.

Position the component in bore.

2.

Select three equilateral mounting points.

3.

Determine the radial gap at those points.

4.

Select and cut appropriate shim stock for each point.

5.

Bond the shims to bore at mounting points using Loctite® Black Max® 380 (480*).

6.

Assemble per instructions on page 27.

EMERGENCY REPAIR ONLY!

Due to the nature of the damage, this should be considered a temporary repair until the unit can be replaced.

* Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

HOUSED COMPONENTS

,,,, ,,,,

,,,, ,,,,

,,,, ,,,,

242® (243*) Bead

1.

Clean the housing I.D. and seal O.D. with Loctite® ODC-Free Cleaner & Degreaser.

2.

Spray both the housing and seal with Loctite® 7649 Primer N.

3.

Apply a bead of Loctite® 242®(243*) Threadlocker to the leading edge of metallic seal O.D.

Note: Virtually any Loctite® Threadlocking product will work here. Low strength liquid is recommended due to normal gap and strength requirement.

4.

Install as usual.

5.

Wipe off excess.

6.

Allow to cure 30 minutes.

Note:



Loctite® 242® (243*) Threadlocker is normally used with worn seal housings to prevent leakage or slippage.



It is not generally necessary to remove pre-applied sealant from seal O.D.

* Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

RETAINING COMPOUNDS

Application Product Primer

Shaft Mount – Press fit Retaining Compound 609 (603*) NONE

Shaft Mount – Slip Fit Small Gap (.002" Radial max.) Larger Gap (.010" Radial max.) Maximum Strength (.010" Radial max.) Retaining Compound 680 Maximum Temperature (400°F) (.008" Radial max.) Retaining Compound 609 (603*) QUICK METAL® 660 Retaining Compound 620 N N T T

Housing Mount – Press Fit Maximum Strength Low Strength Retaining Compound 609 (603*) Threadlocker 242® (243*) NONE NONE

Housing Mount – Slip Fit Maximum Strength High Strength Controlled Strength Low Strength Retaining Compound 680 QUICK METAL® 660 QUICK METAL® 660 Threadlocker 242® (243*) NONE NONE N N

Note:



Softer metals (Aluminum, Bronze, etc.) provide lower shear strengths than ferrous components.



Excessive gap reduces shear strengths.



Ideal surface finish — 50 to 80 rms.

Refer to Technical Data Sheets for more information.

* Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

BONDING

I. JOB EVALUATION — Answer These Questions.

A. What materials are to be bonded? What kind of rubber, plastic, etc.? Porous? Slick? Rough?

B. What kind of service? Operating temperature? Impact? Moisture or water exposure?

C. What kind of stresses? Avoid peel or cleavage!

D. Is gap filling or bridging needed? How much?

E. What cure speed or “return to service” time is needed?

II. ADHESIVE SELECTION (See page 33.)

III. SURFACE PREPARATION

1.

Part must be clean. No oil. No grease. No residue.

2.

Remove paint from bond area for maximum strength.

3.

Roughen smooth surfaces with emery cloth.

4.

Treat selected “hard to bond” materials as directed:

a.

Polyethylene, etc. – Use Loctite® Prism® Primer 770 or 793.

b.

PTFE – Use appropriate etching agent.

5.

Alcohol wipe parts cleaned with water-based “safety” cleaners.

IV.

APPLICATION TECHNIQUES/TIPS

A. Read and follow adhesive package instructions.

B. Use the minimum amount of adhesive to one part only.

Apply activator (if required) to other part.

C. Avoid “jiggling” mated parts. Apply clamp pressure if possible.

D. Allow maximum cure time possible. See technical data for

recommended cure times.

V.

QUESTIONS? Call Loctite Technical Information. See back cover for the Loctite Technical Information number in your area.

LOCTITE MAINTENANCE PRODUCTS

BONDING

TYPES OF JOINTS

LAP/OVERLAP JOGGLE LAP BUTT GOOD GOOD FAIR/POOR

SCARF SINGLE STRAP DOUBLE STRAP

FAIR GOOD BEST

TYPES OF STRESSES

TENSILE COMPRESSIVE CLEAVAGE

FAIR GOOD POOR

SHEAR PEEL GOOD POOR

DESIGN GUIDELINES

1.

Maximize shear/minimize peel and cleavage.

2.

Maximize compression/minimize tensile.

3.

Joint width more important than overlap.

LOCTITE MAINTENANCE PRODUCTS

BONDING

PRODUCT

PRISM® 454 – A surface insensitive gel instant adhesive for common and “hard to bond” materials. Excellent for porous materials and large gaps.

BLACK MAX® 380 (480*) – A toughened instant adhesive for severe environments. Superior impact, temperature, and moisture resistance. Slightly slower fixturing (45-60 seconds).

TAK PAK® Accelerator 7452 or 712 – A spray mist for fast surface curing of all instant adhesives.

PRISM® Primer 770 – Permits bonding of polyethylene, polystyrene, etc. Allow 24 hour adhesive cure time for maximum strength.

DEPEND® 330 – A structural acrylic adhesive used for general purpose, severe environments and less than optimum cleanliness applications. Works on most surfaces except rubber and polyethylene.

FIXMASTER® FAST CURE EPOXY – A two-part epoxy used in rough service, severe environments or large gap applications.

TYPICAL APPLICATIONS

Plastics, rubber, foam, ceramics, felt, cork, wood, etc.

Weatherstripping, name tags, pad mounts, etc.

Tacking jumper wires on PC boards, strain relief, temporary jig placement, etc.

Wear pads, bumpers, buckets, etc.

Sheet metal, glass, fiberglass, composites, wood, etc.

Casting or case repair, sealing punctures, pin holes, etc.

* Worldwide or Application-Specific Alternative

LOCTITE MAINTENANCE PRODUCTS

RUSTPROOFING

SURFACE PREPARATION — OLD STEEL:

Loose or “flaky” rust must be removed. Only conversion of firmly bonded rust will result in durable protection. Oil, grease, old paint, mill scale, form oil, fingerprints and water soluble surfaces and chlorides must be removed to allow Loctite® Extend® to react with rust.

Loose rust, mill scale and oil paint should be removed preferably by power wirebrushing, followed by rinsing with water to remove powder and solubles. Manual wirebrushing, chipping, scraping and particularly rotopeen­ing can also be used. Oil, grease, form oil and fingerprints should be removed before loose rust. Ideal surfaces will show light rust as well as bare metal surfaces.

RUST CONVERSION TIME AND APPEARANCE:

Two coats of Loctite® Extend® are recommended.

On lightly rusted steel (that has been wirebrushed), the first coat will start to develop a violet color within 60 seconds. This will become satin to flat black in appearance. The second coat should dry to a satin black appearance.

On heavily rusted steel (that has been wirebrushed), the first coat should develop a purple-black color within seconds. The second coat should dry to a black color with gloss varying from flat to satin. The second coat should be applied within 15-30 minutes of the first coat.

APPLICATION CONDITIONS:

Loctite® Extend® may be applied when surface and air is between 50°F minimum and rising and 90°F maximum and falling. Reaction is slower at lower temperatures. If temperature is too hot, film may surface dry and bubble. High humidity is beneficial; it slows drying but assists rust conversion. Extend® should not be applied in conditions of condensing humidity (e.g. fog, dew), on ice, in rain or in heavy sea (salt) spray atmospheres. Steel surface may be damp but not wet (i.e. continuous visible film of water). DO NOT APPLY LOCTITE® EXTEND® TO SURFACES IN DIRECT SUNLIGHT.

APPLICATION EQUIPMENT METHODS:

Loctite® Extend® may be applied by brush, roller, or spray. Brush or roller is suitable for small areas. Avoid sags and ridges and keep edges wet by coating about a square yard at a time. Roll away from previously coated area then roll back. Do not pour unused material back into the original container. NEVER add solvents to Loctite® Extend®.

Spray application is recommended for larger areas. Airless spray equipment is faster, and provides more effective conversion due to improved surface penetration. Conventional air-spray equipment may be used, but Loctite® Extend® may require thinning up to 10% with water for proper spraying.

LOCTITE MAINTENANCE PRODUCTS

CLEANING

In general, Natural Blue® cleaning effectiveness is enhanced by:

a.

Higher Natural Blue® Cleaner & Degreaser

concentrations;

b.

Longer cleaner on-part times;

c.

Dilution with warm water (150°F to 180°F);

d.

Agitation of parts or scrubbing.

DIRECTIONS

1.

Dilute Natural Blue® concentrate with water to most economical/effectiveness level. See package labels for suggested ratios.

2.

Spray, dip or wipe dilution onto parts or surface to be cleaned.

3.

Soak parts or scrub (if needed).

4.

Flush soil/cleaner mixture off of parts or surfaces with water.

5.

Disposal: Natural Blue® contains no hazardous ingredients. It should be disposed of in accordance with state and local regulations and will not harm sewage treatment microorganisms. Once Natural Blue® is mixed with hazardous waste, it must be treated as hazardous waste and disposed of accordingly.

Note: Loctite® ODC-Free Cleaner & Degreaser is recommended for cleaning substrates before Loctite® machinery adhesive use.

For fast, effective hand cleaning without skin-irritating petroleum solvents, use LOCTITE® ORANGE Natural Citrus Hand Cleaner. Available with or without pumice, in cream or lotion formula, LOCTITE® ORANGE waterless hand cleaner removes grease, grime, paint, oil and ink and contains aloe and lanolin to keep hands from cracking and drying out. It’s even biodegradable.

LOCTITE MAINTENANCE PRODUCTS

TROUBLESHOOTING

1.

What type failure is occurring? Has the application worked before?

2.

Was proper and adequate adhesive/sealant used?

3.

Was proper and adequate primer/activator used?

4.

Do service conditions exceed the capability of the adhesive sealant?

(a)

operating temperature (c) fluid compatibility

(b)

excessive pressure too soon (d) impact on environment (instant adhesives)

5.

Were parts adequately cleaned prior to applying adhesive? Note: If adhesive failure, is cured residue on one or both parts? If one part is bare, check that part for contamination.

6.

Were proper assembly techniques utilized?

7.

Was adhesive/sealant allowed adequate cure time prior to service?

8.

Do assembly/part conditions exceed capability of the adhesive/sealant?

(a)

excessive gaps (c) improper joint design

(b)

component materials (d) inadequate clamping/fixturing

9.

If additional assistance is required, please call our LOCTITE TECHNICAL INFORMATION LINE. See back cover for the Loctite Technical Information number in your area.

Note: Reference Materials

a.

Product selection, cure times, gap fill, etc.; use Product Selector

Slide Rule (LT-776)

b.

Fluid Compatibility Chart (LT-836)

The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others over whose methods we have no control. It is the user’s responsibility to determine suitability for the user’s purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that may be involved in the handling and use thereof.

In light of the foregoing, LOCTITE CORPORATION SPECIFICALLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARISING FROM SALE OR USE OF LOCTITE CORPORATION’S PRODUCTS. LOCTITE CORPORATION SPECIFICALLY DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING LOST PROFITS.The discussion herein of various processes or compositions is not to be interpreted as representation that they are free from domination of patents owned by others or as a license under any Loctite Corporation patents which may cover such processes or compositions. We recommend that each prospective user test the proposed application to determine its suitability for the purposes intended prior to incorporating any product or application in its manufacturing process using this data as a guide. Some products may be covered by one or more United States or foreign patents or patent applications.

LOCTITE MAINTENANCE PRODUCTS

ORDERING

CATEGORY SIZE ITEM NO.

THREADLOCKERS

222MS SMALL SCREW 10 ml bottle 22221 50 ml bottle 22231 250 ml bottle 22241

242® REMOVABLE 10 ml bottle 24221 50 ml bottle 24231 250 ml bottle 24241

243 REMOVABLE 10 ml bottle 24077 50 ml bottle 24078 250 ml bottle 24079

262 PERMANENT 10 ml bottle 26221 50 ml bottle 26231 250 ml bottle 26241

277 LARGE STUD 10 ml bottle 21434 50 ml bottle 27731 250 ml bottle 27741

290 WICKING 10 ml bottle 29021 50 ml bottle 29031 250 ml bottle 29041

THREAD SEALANTS

545 HYDRAULIC/PNEUMATIC SEALANT 10 ml bottle 32439 50 ml bottle 54531 250 ml bottle 54541

564 LOWER STRENGTH 50 ml tube 28754 250 ml tube 28755

565 CONTROLLED STRENGTH 50 ml tube 56531 250 ml tube 56541 300 ml cartridge 56571

567 HIGH TEMPERATURE 50 ml tube 56747 250 ml tube 56765 16 oz. brush top 33241

RETAINING COMPOUNDS

609 GENERAL PURPOSE 10 ml bottle 60921 50 ml bottle 60931 250 ml bottle 60941

620 HIGH TEMPERATURE 10 ml bottle 62015 50 ml bottle 62040 250 ml bottle 62070

660 QUICK METAL® PRESS FIT REPAIR 6 ml tube 66010 50 ml tube 66040 250 ml tube 30287

680 HIGH STRENGTH/HIGH VISCOSITY 10 ml bottle 68015 50 ml bottle 68035 250 ml bottle 68060

LOCTITE MAINTENANCE PRODUCTS

ORDERING

CATEGORY SIZE ITEM NO.

GASKETING

510 GASKET ELIMINATOR® HIGH TEMPERATURE 50 ml tube 51031 250 ml tube 51041

515 GASKET ELIMINATOR® 6 ml tube 51517 50 ml tube 51531 300 ml cartridge 51580

518 GASKET ELIMINATOR® 6 ml tube 51817 50 ml tube 51831 300 ml cartridge 51845

MASTER GASKET® KIT 25 ml syringe 22423 300 ml cartridge 22424

INSTANT GASKET 4 oz. can 30684 5 oz. cartridge 30509 7 oz. can 30507

598 BLACK RTV SILICONE GASKET MAKER 70 ml tube 59830

8.75 oz. can 59866 300 ml cartridge 59875

587 BLUE RTV SILICONE GASKET MAKER 70 ml tube 58730

8.75 oz. can 30567 300 ml cartridge 58775

5920 COPPER RTV SILICONE GASKET MAKER 70 ml tube 30542 300 ml cartridge 82046

5699 GREY RTV SILICONE GASKET MAKER 70 ml tube 18718 300 ml cartridge 18581

ADHESIVES

330 DEPEND® NO-MIX 25 ml syringe kit 20251 250 ml tube kit 20252 250 ml tube 33058 300 ml cartridge 33064

380 BLACK MAX® TOUGHENED 3 gm tube 38004 1 oz. bottle 38050 1 lb. bottle 38061

404 QUICK SET™ 1/3 oz. bottle 46551 4 oz. bottle 46548 1 lb. bottle 46561

454 PRISM® SURFACE INSENSITIVE GEL 3 gm tube 45404 20 gm tube 45440 300 gm cartridge 45478

480 PRISM® TOUGHENED 20 gm bottle 48040 1 lb. bottle 48061

FIXMASTER® FAST CURE EPOXY 10-4 gm cups 21425 10-1 oz. cups 21426

LOCTITE MAINTENANCE PRODUCTS

ORDERING

CATEGORY SIZE ITEM NO.

PRIMERS

7471 PRIMER T (Acetone) 1.75 fl. oz. bottle 19267

4.5 oz. aerosol 22477

7649 PRIMER N (Acetone) 25 gm aerosol 21347

1.75 fl. oz. bottle 19269

4.5 oz. aerosol 21348

770 PRISM® PRIMER (Heptane) 1.75 fl. oz. bottle 18396

712 TAK PAK® ACCELERATOR (Isopropyl Alcohol) 1.75 fl. oz. bottle 20352

7452 TAK PAK® ACCELERATOR (Acetone) 1.75 fl. oz. bottle 18580

LUBRICANTS

C5-A® COPPER ANTI-SEIZE 8 oz. brush top 51147

1 lb. brush top 51007

12 oz. aerosol 51003

NICKEL ANTI-SEIZE 8 oz. brush top 77124

1 lb. brush top 77164

12 oz. aerosol 51286

SILVER GRADE ANTI-SEIZE 8 oz. brush top 76732

1 lb. brush top 76764

12 oz. aerosol 76759

CLEANERS

LOCTITE® ORANGE pumice formula (lotion) 7.5 fl. oz. bottle 25108

15 fl. oz. bottle 25116

1 gallon pump 25218

LOCTITE® ORANGE smooth formula (lotion) 7.5 fl. oz. bottle 23108

15 fl. oz. bottle 23116

1 gallon pump 23218

LOCTITE® ORANGE pumice formula (cream) 14 oz. tub 35013

LOCTITE® ORANGE smooth formula (cream) 14 oz. tub 33013

NATURAL BLUE® CLEANER & DEGREASER 24 fl. oz. spray 82249

1 gallon bottle 82251

ODC-FREE CLEANER & DEGREASER 15 oz. aerosol 22355

16 fl. oz. pump spray 20162

GENERAL MAINTENANCE

EXTEND® RUST TREATMENT 10.25 oz. aerosol 30539

1 quart bottle 75430

1 gallon bottle 75448

FORM-A-THREAD® STRIPPED THREAD REPAIR 4.8 ml syringe 28654

O-RING SPLICING KIT Kit 00112

For product availability, technical information and material safety data sheets (MSDS) call:

Loctite Corporation, U.S.A. 1001 Trout Brook Crossing Rocky Hill, CT 06067

1-800-LOCTITE (562-8483)

Loctite Canada Inc. 2225 Meadowpine Blvd. Mississauga, Ontario L5N 7P2

1-800-263-5043

Loctite Company de México, S.A. de C.V. Calzada de la Viga s/n, Fracc. Los Laureles Loc. Tulpetlac, C.P. 55090 Ecatepec de Morelos, Edo. de México, México

01-800-849-9412

Or visit Loctite at: www.loctite.com

Loctite Industrial

All trademarks in this brochure, except where noted, are the property of or used under license by Loctite Corporation, U.S.A. © Copyright 2001. Loctite Corporation. All rights reserved. 0103-215/LT-1475B

If you liked this, please tell us:
  • Facebook
  • Twitter
  • email
  • Print
  • Add to favorites
  • Google Bookmarks
  • RSS
This entry was posted in MRO Supplies and tagged , , , , , , , , , . Bookmark the permalink.

Comments:

Your email address will not be published. Required fields are marked *

*

Captcha Captcha Reload

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>