Application of Static Charge Dissipation to Mitigate Electric Discharge Bearing Currents White Paper

Download (PDF, 461.33KB)

Application of Static Charge Dissipation to Mitigate
Electric Discharge Bearing Currents

Annette Muetze, Member, IEEE, and H. William Oh, Member, IEEE

Abstract—Today, the physical cause-and-effect chains of inverter-induced high-frequency bearing currents have been well understood, but little has been known on not only theoretically possible, but also cost-effective mitigation techniques for a certain drive con.guration. This paper focuses on the mitigation of dis­charge bearing currents, which occur predominantly with smaller motors of up to several kilowatts. We present a new mitigation tech­nique where any voltage build-up across the bearing is discharged via static charge dissipation through a parallel path before an elec­tric breakdown inside the bearing occurs. The technique is based on the .eld emission effect, has ultralow friction and negligible wear, and is very robust toward contamination, when compared with conventional carbon-based brushes.

Index Terms—Bearings (mechanical), common-mode voltage, electric breakdown, electric .eld effects, variable-speed drives.

NOMENCLATURE BVR Bearing voltage ratio. CM Common-mode. DE Drive-end. EDM Electric discharge machining. ESD Electrostatic discharge. F-N Fowler–Nordheim. HVAC Heating, ventilation, airconditioning. NDE Nondrive-end. VFD Variable-frequency drive. a Constant. b Constant. d Gap spacing. p Pressure. vbea Voltage across the bearing. vcom Common-mode voltage. Ac Cross-sectional area. Cwr Capacitance between stator-winding and rotor. I Current. E Electric .eld-strength. Em Microscopic electric .eld-strength at the microscopic

surface of the contact. Rf Resistance between the two poles of the micro.ber brush. V Voltage.

Paper IPCSD-07-060, presented at the 2007 IEEE International Electric Ma­chines and Drives Conference, Antalya, Turkey, May 3–5, and approved for pub­lication in the IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS by the Indus­trial Drives Committee of the IEEE Industry Applications Society. Manuscript submitted for review May 8, 2007 and released for publication July 26, 2007.

A. Muetze is with the School of Engineering, University of Warwick, Coven­try CV4 7AL, U.K. (e-mail: a.muetze@warwick.ac.uk).

H. W. Oh is with Electro Static Technology, Mechanic Falls, ME 04256 USA (e-mail: hwoh@est-static.com). Color versions of one or more of the .gures in this paper are available online

at http://ieeexplore.ieee.org. Digital Object Identi.er 10.1109/TIA.2007.912758

VB Breakdown voltage.

ß Total electric .eld enhancement factor.

ßg Geometric electric .eld enhancement factor.

ßm Microscopic electric .eld enhancement factor.

. Pressure-gap product.

I. INTRODUCTION

I

NVERTER-INDUCED high-frequency bearing currents are a parasitic effect that can occur in variable-speed drive sys­tems. Different types of bearing currents that have different cause-and-effect chains can be distinguished. With the advent of modern drive technology, these phenomena have been well recognized and physical explanations have been given [1]–[15]. While the cause-and-effect chains have been understood, little has still been published not only on theoretically possible, but also on cost-effective mitigation techniques for a certain drive con.guration.

Among the different bearing current types that have been identi.ed, this paper focuses on the mitigation of high-frequency discharge bearing currents [also “electric discharge machin­ing (EDM)-bearing currents”]. These occur predominantly with smaller motors of up to several kilowatts [14], [15]. Common mitigation techniques are common-mode (CM) voltage .lters, hybrid/ceramic bearings, and—sometimes—brushes.

We present a new mitigation technique that is based on static charge dissipation. Here, any voltage build-up across the bearing is discharged due to the electric .eld emission effect through a parallel path before an electric breakdown inside the bearing occurs. The technique has ultralow friction and negligible wear, and is very robust toward contamination, when compared to conventional carbon-based brushes. It is also easy to install and cost-effective.

The paper is organized as follows: First, a brief review of EDM-bearing currents is given in Section II. Then, the princi­ple idea of the presented mitigation technique is presented in Section III, followed by a brief summary of the required back­ground information of electrostatic discharge (ESD) effects in Section IV. In the main part of the paper, the theory of the proposed technique is discussed (Section V) and experimental results are presented (Section VI). Conclusions are drawn at the end of the paper in Section VII.

II. REVIEW:DISCHARGE BEARING CURRENTS

A. Physical Cause-and-Effect Chain

If no additional measures, like special .lters or control schemes, are applied, a voltage-source inverter presents a voltage-source in the CM circuit. The generated CM voltage

0093-9994/$25.00 © 2008 IEEE

Fig. 1. At electrically insulating lubrication .lm, the voltage across the bearing (vbea) mirrors the CM voltage (vcom); squirrel-cage induction motor, 215 TC frame, 10 hp rated power, motor speed 1800 r/min.

TABLE I

RANGES OF THE VOLTAGE ACROSS THE BEARING

Fig. 2. Phycial cause-and-effect chain of EDM-bearing currents.

contains high-frequency components that interact with capac­itances inside the machine that have not been of in.uence at line operation. As a result, at electrically insulating (“intact”) lubrication .lm, the voltage across the bearing vbea mirrors the CM voltage vcom (Fig. 1). The voltage across the bearing is also frequently referred to as “shaft voltage.” It should be noted that the voltage across the bearing has a very different nature than the “shaft” voltage along the shaft that can be generated by high-frequency CM currents.

The capacitive voltage divider between vbea and vcom is com­monly referred to as “bearing voltage ratio” (BVR) (e.g. [4], [5]). The BVR is typically in the order of several percent, with an upper bound of 10% for “typical” machines [16].

Table 1 gives an overview of the ranges of the maximum voltage across the bearing for different 3 ph supply voltages and BVR = 1–10%. Increased voltage at the motor terminals due to voltage re.ection can increase these values additionally.

When a breakdown of the electrically loaded oil .lm between the rolling elements and the running surface takes place, a dis­charge bearing current pulse occurs (Figs. 2 and 3).

Fig. 3. Measured discharge bearing current; induction motor, frame size 160 mm, 11 kW rated power, motor speed 1500 r/min, bearing temperature ˜30.C [14]; icom: stator CM current; ibea, bearing current; NDE, nondrive-end; DE, drive-end. The voltage across the bearing changes with every switching in­stant (occurrence of a stator-winding CM current, traces 1 and 4), the discharge bearing-current, however, occurs independently of the switching instant and mostly in one of the bearings (traces 2 and 3).

Depending on the operating conditions of the machine, the threshold voltage for a breakdown to occur is approximately 5–30 V, where the occurrence of the breakdowns itself is a statistically distributed effect [14]. A comparison with Table I shows that the voltage across the bearing at electrically insulat­ing lubricating .lm can easily exceed the threshold voltage.

A lot of the literature referred to in the following has been taken from the context of electrostatic discharging and electric breakdown of microelectronic devices. Therefore, we would like to emphasize that the charging mechanism of the bearings as described is fundamentally different from the “triboelectric” charging by separation. As opposed to the capacitively coupled charging of the bearing, the triboelectric charging occurs when two materials with different electron af.nity that have been in contact are separated. The degree to which the charge stays on the materials depends mostly on their conductivities and initial charge densities [17].

B. Common Mitigation Techniques

Commonly, one of the following mitigation techniques for discharge bearing currents are used with commercial applications.

1) CM voltage .lters are complex circuits that are designed to reduce or eliminate the CM voltage, notably its high-frequency components. The .lters are a rather costly addi­tion to the drive system. Often, they are applied to attenuate electromagnetic noise, and then, are combined with dif­ferential noise .lters. It should be mentioned that, on the academic level, comparatively a lot is known about the de­sign of special modulation techniques and inverter-output .lters to eliminate the CM voltage.

2) Carbon brushes use electrically conductive carbon graphite and provide an electrical connection between the motor shaft and the frame parallel to the bearing. A graphite .lm deposits on the contact area during sliding. Humidity creates a water layer on the graphite, thereby rendering the brushes self-lubricating. Commonly quoted problems are excessive wear and hot-spotting/thermal moulding as the contact is transferred to fewer, expanded, more fragile spots during the sliding, as well as brush dusting/low-humidity lubrication [18]. Maintaining good electrical contact at the high frequencies of the CM

Fig. 4. Points of impact of different mitigation techniques on the EDM-bearing current physical cause-and-effect chain.

voltage poses additional challenges on the brush design and installation.

3) Hybrid/full ceramic bearings have ceramic (silicon ni­tride) rolling elements and quality (alloy or carbon) steel races or both ceramic rolling elements and races, respec­tively. Thereby, they introduce a large insulating gap into the bearing and prevent electric discharge in the bearing. However, the charges on the rotor seek an alternate path to the ground, typically through the attached equipment if the rotor is not isolated. Irrespective of bearing currents, ceramic bearings are mostly selected for mechanical rea­sons. These bearings are signi.cantly more expensive than conventional steel bearings. In addition, because ceramic bearings and steel bearings differ in compressive strength, ceramic bearings must be resized in most cases to handle mechanical static and dynamic loadings.

The points of impact of these mitigation techniques on the EDM-bearing current physical cause-and-effect chain are illus­trated in Fig. 4.

III. PRINCIPLE IDEAOFTHE PROPOSED

MITIGATION TECHNIQUE

The proposed mitigation technique has the same point of im­pact as brushes do, that is, it prevents the voltage build-up across the bearings (Fig. 4). However, in contrast to the spring-loaded mechanism of conventional carbon brushes, the technique has ultralow fricition and negligible wear, and is relatively robust toward contamination, and thus, it is free of the problems that are commonly quoted with brushes (Section II-B). The electric contact between the motor frame and the shaft is established using the electric .eld emission effect. In order to understand this technique, it is important to well distinguish between the different ESD mechanisms and their associated length scales of the gaps. In the next section, we .rst provide an overview of this topic to help the reader understand the “overall picture” (Sections IV-A through IV-D), and give a summary of the key values (Section IV-E) that we use in the discussion of further details of the proposed new mitigation technique (Section V).

IV. BACKGROUND ON ELECTROSTATIC

DISCHARGE MECHANISMS

A. Electric Contact Without Mechanical Contact

In order to understand the mitigation technique for EDM-currents presented in this paper, it is important to be aware of

Fig. 5. Qualitative sketch. (a) Paschen curve. (b) Modi.ed Paschen curve based on [25].

the fact that “electric contact” does not necessarily also mean “mechanical contact.” In this section, we explain some mech­anisms to achieve the electric contact without having any me­chanical contact. To this aim, we .rst review the three main prebreakdown current mechanisms and lengths scales (Sections IV-B–IV-D).

B. Gaseous Discharge for “Large” Gaps (Above ˜5 µm)

Gaseous breakdown at “large” gaps is commonly described using the Paschen curve that is based on Paschen’s law [19]. The Paschen curve correlates the breakdown voltage VB and the reduced variable . = pd, where p is the pressure and d is the gap spacing. For each pressure–gap product, it predicts a minimum breakdown voltage, the so-called Paschen-minimum (Fig. 5).

The underlying understanding of the breakdown mechanism is the Townsend (avalanche) breakdown in gases. That is, the cascading effect of secondary electrons obtained by collisions and impact ionization of the gas ions accelerating across the gap [20], [21]. The breakdown voltage is affected by the geometrical con.guration of a discharge gap, particularly the shape and the size of the electrodes used in the tests [22], [23].

The Paschen curve is well known. Breakdown for gaps greater than approximately 10 µm has been well studied, and the break­down limit for air at one atmosphere is identi.ed as 3 V/µm (3 kV/mm). The minimum breakdown voltage is approximately 360 V and occurs at a gap spacing of 5 µm, and it increases for smaller gaps [24]. The misconception that the same break­down mechanism would hold for smaller gap spacings is best illustrated quoting [24]:

While the left, rising part of the Paschen curve can be observed at low pressure and large gap spacing, it is not observed for air gaps at atmospheric pressure [25]. One proof of this is the 80 V break­down voltage reported for a 0.12 µm air gap in [26]. Nevertheless, there exists a widespread misconception that there exists a minimum breakdown voltage for air gaps and that if the spacing of a device is scaled-down below ˜ 5 µm, then breakdown will not occur.

C. Electric Field Emission for “Small” Gaps (˜ 5nmto ˜5 µm)

Field emission is a form of quantum tunneling and is also known as Fowler–Nordheim (F–N) tunneling [27]–[29]. It is the process whereby electrons tunnel through a barrier in the presence of a high electric .eld (that is often associated with a deformed surface potential barrier). The potential at which the electrons have suf.cient kinetic energy to do so is commonly referred to as barrier gap or work function potential. As the kinetic energy of the charge carriers has a certain distribution over the population, some of them have enough energy to cross the gap even much below the breakdown voltage.

In contrast to the Frenkel–Powl tunneling commonly used for semiconductor devices, the F–N tunneling does not rely on defects in a material.

The F–N equation relates the current (or the current density) before breakdown and the electric .eld or voltage. The simpli­.ed form is shown as [30]

()

I =aV 2exp - b (1)

V where I is the .eld emission current, V is the voltage, and a and b are constants that contain, among others, the emitting area, work function, a .eld enhancement factor (see later), and functions of the electric .eld and the work function that are approximated as constants. The plot of 1/E versus ln(I/E2) [or 1/V versus ln(I/V 2)] is referred to as the F–N plot. It allows to verify whether a mea­sured current is due to .eld emission, in which case a straight line with a negative slope is obtained, where the slope is pro­portional to the work function of the metal [29]. The .eld enhancement factor, commonly denoted by ß,in­cludes the enhancement of the electric .eld due to the geometry ßg, and due to the microscopic peaks in the (polished!) contact surface ßm, and can reach more than two orders of magni­tudes [31]. Then,

Em

V =d (2)

ß where Em is the microscopic electric .eld strength at the mi­crosurface of the contact. The electrons resulting from .eld emission can initiate an electric breakdown that occurs when the (local) .eld emission current density (at microscopic level) exceeds a critical value [31]. This electric breakdown due to the .eld emission effect occurring at smaller gaps is included in the little-known modi.ed Paschen curve [25]. It is best explained by quoting [24] again:

The modi.ed Paschen curve shows a platform where the pure Paschen curve would have a minimum which is interpreted as the transition region between the gaseous Townsend avalanche and .eld emission induced breakdown. For smaller gaps (left) of the plateau, breakdown is only due to .eld emission. The breakdown voltage drops to zero. Details of the geometry and the metal electrode prop­erties in.uence the exact location of the transition.

D. Tunneling for “Ultrathin” Gaps

This mechanism does not relate directly to the topic of this paper and we are listing it for completion only. As the gap size decreases, the probability of electrons tunneling across an insulating barrier increases. For “ultrathin” gaps (˜2nm [24]), this can result in a signi.cant tunneling current.

E. Summary of Key Qualitative Results

We are using results published in the context of the micro­electronics industry as the starting point for our theoretical in-

TABLE II

PREBREAKDOWN CURRENT MECHANISMS AND LENGTH SCALES [24]

vestigation [24], [31]–[34]. Though the context of this paper is very different, we will show how these results can be applied to develop a reliable and cost-effective mitigation technique for EDM-bearing currents.

Table II shows a summary of the prebreakdown current mech­anisms and length scales according to [24] and [32], who draw the following conclusions concerning electric breakdown and ESD phenomena for devices with nanometer-to-micron gaps:

“1) Breakdown is easy across gaps with spacings <5 µm and

is well below the ˜360 V Paschen curve minimum. 2) The prebreakdown current mechanism is .eld emission. 3) The modi.ed Paschen curve that includes .eld emis­

sion effects can be used to predict the breakdown of microdevices.” Similar conclusions have been drawn by the authors of [31]: “1) For closely spaced contacts in air, Paschen‘s law is only valid for contact gaps greater than about 6 µm. 2) For contact gaps less than about 4 µm, the breakdown voltage Vb in air is a linear function of the contact gap.

3) For contact gaps less than about 4 µm, the electric .eld at a microprojection ...to produce a very high current den­sity, .eld emission electron beam ...Electrical breakdown between the contact is achieved ....”

In the following, we are summarizing some key qualitative results.

1) Metal–air–metal [24]: VB/d =156 V/µm (conservative estimate, neglecting the in.uence of the curvature and the .lm); breakdown volt­ages 151 and 135 V (two samples), 0.9 µm gap; glass deposited on a 100 nm thick chrome and a chrome .n­ger with 2 µm diameter. The modi.ed Paschen curve was obtained for gap spacings between 0.9 µm and 4.0 µm, where the knee was found at 2 µm. The .eld emission behavior was con.rmed via the F–N plot.

2) Metal–air–metal [31]: VB/d =110 V/µm and VB/d =65V/µm from data ob­tained in [33] and [34]; [33]: Fe polished needle with

0.6 mm diameter, 0.05 mm radius, and silver disc, gap spacings 0.2–40 µm; [34]: very carefully developed contact system, clean room measurements, Ni, Al, and brass contacts—no difference in VB was found, showed that Paschen’s law is not applicable for gaps between 0 and 4 µm.

V. PROPOSED MITIGATION TECHNIQUE IN THEORY

A. Introduction

With our application, we do not consider ESD as an unwanted, destructive effect, but use the underlying phenomena as a means to discharge the voltage across the bearing vbea through a paral­lel path. Thereby, we prevent an electric breakdown occurring inside the bearing that would result in a potentially harmful EDM-bearing current pulse (Fig. 4). By using ESD and the electric .eld emission effect as mechanisms to provide an elec­trical contact, we bypass the problems commonly quoted along with mechanical-contact based carbon brushes (Section II-B).

B. Discussion of Orders of Magnitudes and Requirements

The values for vbea shown in Table I (Section II) are far be­low the Paschen minimum (Section IV-B). Thus, considering only the gaseous, Townsend breakdown mechanism, one would mistakenly draw the wrong conclusion that vbea could not be discharged by ESD through a path parallel to the bearing. How­ever, exploiting the .eld emission effect, this can be achieved successfully.

To this aim, the following requirements must be met:

1) Locally, the electric .eld strength for a breakdown due to

.eld emission to occur must be achieved.

2) The voltage across the bearing needs to be discharged

through the parallel path before an electric breakdown

along with a potentially harmful EDM-bearing current

pulse occurs inside the bearing.

3) The two poles must have a “good” electrical connection

to the outer and inner bearing race respectively.

Similar to the situation with brushes, 3) can be achieved by taking the machine end-shield and the shaft as the two poles, respectively. We will discuss more details of this aspect later (Section V-D), and .rst address 1) and 2).

In order to ful.ll 1) and 2), a very small gap spacing and a geometry that results in local .eld enhancement, such as elec­trically conducting tips with very small diameters, would need to be provided. (Here, “very small” refers to the dimensions that drives-engineers usually deal with.) Approximating the results summarized earlier (Section IV–E) with VB /d ˜ 100 V/µm and 2 µm tip diameter, breakdowns at ˜2 V would require gap spac­ings of 0.02 µm. This is even at the very low end of the surface roughnesses that are achieved either with polishing or super-.nishing [35]. Thus, it is not directly applicable here as such. However, lower VB /d ratios could be achieved by exploiting the in.uence of the local electrical .eld concentration with very sharp edges, and thus, with smaller tips. Without electric .eld distortion by dielectric materials around the electrode tips, ap­proximating the .eld enhancement factor ß . r-1 , where r is the radius of the tip, VB /d ˜ 1 V/µm can be found at 0.02 µm tip diameter. Then, breakdowns at ˜2 V would require gap spacings of 2 µm. With typical roughnesses of approximately 1.6–6.3 µm, this is at the low end of the surface roughnesses of machine shafts. Though a surface polish could be applied to the machine shaft, this would require additional work, and the gap spacing would be dif.cult to maintain under normal operating conditions.

C. Solution: Conductive Micro.bers

It would be very dif.cult—and for a commercial applica­tion probably almost impossible—to develop a system of solid metallic .nger tips that could be maintained at the required distance to the shaft. However, conductive micro.bers do pro­vide a good alternative solution. These are .bers with strands less than one denier, where one denier equals 1 g per 9000 m of .ber. They are mechanically .exible and yet high strength, high-stiffness .bers.

Such conductive micro.bers have very small diameters of less than 10 µm. Under the in.uence of an applied voltage, they emit current due to the electric .eld emission effect (Section IV-C) because of the locally highly enhanced electric .eld at the trun­cated .ber tips. Due to their mechanically .exible structure, if applied with the correct interference, the micro.bers can main­tain contact with the surface, thereby compensating the surface roughness of the shaft. In spite of the rotating movement of the shaft, the micro.bers only “see” one nonrotating second pole, and the rotation of the machine shaft does not affect the functional capability of the .bers.

When a multitude of such .bers is assembled around a ma­chine shaft, a high density of contact points is given, and many parallel paths

1) either for current to .ow

2) or for a breakdown to occur

are provided.

1) When the mechanical contact is also electrically “good,”

current .ows through the micro.bers.

2) When the micro.bers lose good electric contact by me­

chanical contact, a breakdown due to local .eld emission

will occur somewhere along the circumference, thereby

reestablishing the electric contact.

In order to ful.ll 1), the micro.bers must be able to carry the current that is driven by the voltage across the bearing vbea. This current is mainly a function of vbea and Rf , the resistance between the micro.bers and the shaft, which is a strong function of the current. Furthermore, in order to protect the bearing, the resistance has to be so small that the voltage across the resistance does not exceed the bearing breakdown voltage. To assess the orders of magnitudes that affect the .ber design, we .rst approximate the current density of the .bers with 1010 A/m2 (conservative estimate, using [31] as starting point). In this case, a .ber with a 1 µm tip and thus Ac=0.78 × 10-12 m2 cross-sectional area would be able to carry 7.8 mA. To carry a current of 7.8 A, 1000 .bers would be required. In the next step, we set the resistance Rf to zero. Then, the CM voltage is in parallel to the capacitance between the stator-winding and the rotor Cwr , as the rotor is shorted to the frame of the machine. Taking by intention (very) high values for both the dv/dt of the CM voltage, 2 kV/µs, and the value of Cwr , 500 nF, we obtain a current of 2 kV/µs × 500nF = 1 A. This current is almost one order of magnitude smaller than the estimated current carrying capability with as few as 1000 .bers.

The previous rough calculations illustrate that a tradeoff has to be made: properly designed .bers: 1) carry the cur­rent in parallel to the bearing and prevent voltage to build up across the bearing and 2) lead to a breakdown the mo­ment a “good” electric contact between the .bers and the shaft is lost.

The close view of a realization of such a ring of conductive micro.bers and the ring as it is mounted on a machine are shown in Figs. 6 and 7, respectively.

TABLE III

DATA OF THE TEST DRIVES

Fig. 6. Conductive micro.bers assembled in rings to form static charge dissi­pation devices for mitigation of EDM-bearing currents.

Fig. 7. Ring with conductive micro.bers (static charge dissipation device) mounted at a machine shaft to obtain discharge of the voltage across the bearing through a parallel path (four-pole squirrel-cage induction motors with 1 hp rated power and 143 TC frame).

In this paper, we focus on the application of such brushes as mitigation technique for EDM-bearing currents. These currents occur predominantly with rather small motors up to several kilowatts rated power. Such brushes can also be used with larger motors for current-carrying purposes. This subject will be the topic of a different publication.

D. Comments on Robustness and Mounting

If properly designed, the interference between the .bers and the shaft can have ultralow friction, giving a technique that can be considered as free of direct frictional wear. Furthermore, the .bers can be designed to cut through contaminants such as given by oily, greasy, moist, and dusty environments. The .bers can be assembled to give a ring with a rather slim design that can be mounted on both the nondrive-and drive-end of a machine with rigid mounting plates or mounting brackets, where the electric contact is ensured with screws (Fig. 7). Thereby, no machining is required, and the installation of the device is relatively simple. In Section VI, we will report on the test results of the proposed micro.ber solution. On an additional long-term test of 8700 h of operation, it was also found that the performance of the conductive micro.bers was not changed. Thousands of micro.ber rings have been installed in diverse applications such as paper mills, hospitals, and other heating, ventilation, and air conditioning (HVAC) fans over the last two years. Reports from the .eld have shown that the conductive

Fig. 8. CM voltage vcom and voltage across the bearing vbea with ring of conductive micro.bers; motor MB, 215 TC frame, 10 hp rated power, motor speed 1800 r/min, inverter Ia, carrier frequency 12 kHz, compare with Fig. 1

micro.ber ring is very effective and an economical solution to variable-frequency drive (VFD) related bearing failure.

VI. EXPERIMENTAL RESULTS

A. Test Setup

The ability of rings of conductive micro.bers to prevent a voltage of several volts to build up across the bearing was veri­.ed with a series of tests. We are reporting on selected tests that were carried out with two four-pole 50/60 Hz 230 V/460 V off-the-shelf squirrel-cage induction motors and two off-the-shelf 460 V voltage-source inverters (Table III).

For all con.gurations, the CM voltage vcom and the voltage across the bearing vbea were measured during the operation, both with and without the rings of conductive micro.bers being applied. This was done for different motor speed (up to two times no-load speed), additional grease (“contamination”) on the motor shaft and the .bers, and variable switching frequency. Also, an additional test was carried out with the machine and the ring from micro.bers being applied for 8700 h of operation. The measurements of the voltages were carried out with the help of an arti.cial star-point, 500 MHz voltage probes, and a 600 MHz, 5 GS/s scope.

B. Results

Fig. 8 shows the measured waveforms of vcom and vbea of the same test setup as Fig. 1, but now a ring of conductive micro.bers is applied. When comparing the two .gures, it can be seen that the voltage across the bearing is reduced to a maximum of 4–7 V peak-to-peak and 4 Vp. Thus, the ring prevents the voltage across the bearing to build up to levels where the bearing

TABLE IV OVERVIEW OF THE TESTS SHOWN IN FIGS.1 AND 8THROUGH 10

Fig. 9. CM voltage vcom and voltage across the bearing vbea; motor MA, 143 TC frame, 1 hp rated power, motor speed 1800 r/min, inverter Ia, carrier frequency 12 kHz. (a) Without ring of conductive micro.bers (test T2N). (b) With ring of conductive micro.bers (test T2Y).

is endangered, as the bearing is shorted through a parallel low-resistance path.

For the various con.gurations discussed earlier (Section VI-A), voltage build-up across the bearing and subsequent breakdown could be observed when no additional device was applied. However, with a ring of conductive mi­cro.bers being applied, the voltage was reduced to a maximum of 4–7 V peak-to-peak and 4 Vp, and no breakdown events were observed. With respect to the additional long-term test, the amount of wear was too negligible to alter the performance.

For illustration, the measured traces of vcom and vbea for se­lected con.gurations from the series of measurements are shown in Figs. 8 through 10, where Figs. 9(a) and 10(a) show the

Fig. 10. CM voltage vcom and voltage across the bearing vbea; motor MB, 215 TC frame, 10 hp rated power, motor speed 1800 r/min unless otherwise stated, inverter Ib, 2.5 kHz carrier frequency. (Note: When comparing with Figs. 1, 8, and 9, the lower carrier frequency of the second inverter is also clearly to see.) (a) Without ring of conductive micro.bers (test T3N). (b) With ring of conductive micro.bers (test T3Y). (c) With ring of conductive micro.bers, grease applied on the shaft (test T3G). (d) With ring of conductive micro.bers, motor speed 3600 r/min (test T3S).

measurement results when no additional device was applied, and Figs. 8, 9(b), and 10(b)–(d) show measurement results with a ring of conductive micro.bers being applied. More details of the individual con.gurations are shown in Table IV.

These pictures illustrate well the corrective effect of the ring of conductive micro.bers on the voltage build-up across the bearing and the subsequent breakdown phenomena, thereby con.rming the ability of this device to serve as an ef­fective mitigation technique for electric discharge bearing currents.

VII. CONCLUSION

A new mitigation technique for EDM-bearing currents that uses static charge dissipation has been presented. With this tech­nique, the voltage across the bearing is discharged at very low levels and before an electric breakdown inside the bearing oc­curs. The technique is based on the .eld emission effect, has ultralow friction and negligible wear, and is very robust toward contamination, when compared to conventional carbon-based brushes. With this technique, a high density of contact points given by a multitude of conductive micro.bers that are arranged in parallel to the bearing via a supporting ring is used to pro­vide many parallel paths for current to .ow or a breakdown to occur outside of the bearing. It was shown that it is impor­tant to include the electric .eld emission effect in the theo­retical analysis of the orders of magnitudes of the parameters that are involved in the design process. Furthermore, a series of measurement results that con.rms the effectiveness of the proposed mitigation technique for EDM-bearing currents was presented.

REFERENCES

[1] S. Chen, T. A. Lipo, and D. Fitzgerald, “Modelling of motor bearing cur­rents in inverter drives,” IEEE Trans. Ind. Appl., vol. 32, no. 6, pp. 1365– 1370, Nov./Dec. 1996.

[2] J. Erdman, R. Kerkman, and D. Schlegel, “Effect of PWM inverters on AC motor bearing currents and shaft voltages,” IEEE Trans. Ind. Appl., vol. 32, no. 2, pp. 250–259, Mar./Apr. 1996.

[3] D. Busse, J. Erdman, R. Kerkman, D. Schlegel, and G. Skibinski, “The effect of PWM voltage source inverters on the mechanical performance of rolling bearings,” IEEE Trans. Ind. Appl., vol. 33, no. 2, pp. 567–576, Mar./Apr. 1997.

[4] D. Busse, J. Erdman, R. Kerkman, and D. Schlegel, “Bearing currents and their relationship to PWM drives,” IEEE Trans. Power Electron., vol. 12, no. 2, pp. 243–252, Mar. 1997.

[5] D. Busse, J. Erdman, R. Kerkman, D. Schlegel, and G. Skibinski, “Sys­tem electrical parameters and their in.uence effect on bearing cur­rents,” IEEE Trans. Ind. Appl., vol. 33, no. 2, pp. 577–584, Mar./Apr. 1997.

[6] D. Busse, J. Erdman, R. Kerkman, D. Schlegel, and G. Skibinski, “Char­acteristics of shaft voltage and bearing currents,” IEEE Ind. Appl. Mag., vol. 3, no. 6, pp. 21–32, Nov./Dec. 1997.

[7] A. von Jouanne, H. Zhang, and A. K. Wallace, “An evaluation of mit­igation techniques for bearing currents, EMI and overvoltages in ASD applications,” IEEE Trans. Ind. Appl., vol. 34, no. 5, pp. 1113–1122, Sep./Oct. 1998.

[8] P. Link, “Minimizing electric bearing currents in ASD systems,” IEEE Ind. Appl. Mag., vol. 5, no. 4, pp. 55–66, Jul./Aug. 1999.

[9] A. Binder, R. Aust, and A. Schrepfer, “Bearing currents—A danger to inverter-fed AC-motors?,” Iron Steel Eng., vol. 76, no. 7, pp. 47–52, Jul. 1999.

[10] S. Bell, T. J. Cookson, S. A. Cope, R. A. Epperly, A. Fischer,

D. W. Schlegel, and G. L. Skibinski, “Experience with variable-frequency drives and motor bearing reliability,” IEEE Trans. Ind. Appl., vol. 37, no. 5, pp. 1438–1446, Sep./Oct. 2001.

[11] H. E. Boyanton and G. Hodges, “Bearing .uting,” IEEE Ind. Appl. Mag., vol. 8, no. 5, pp. 53–57, Sep./Oct. 2002.

[12] R. Naik, T. A. Nondahl, M. J. Mel., R. F. Schiferl, and J. S. Wang, “Circuit model for shaft voltage prediction in induction motors fed by PWM-based AC drives,” IEEE Trans. Ind. Appl., vol. 39, no. 5, pp. 1294–1299, Sep./Oct. 2003.

[13] R. F. Schiferl and M. J. Mel., “Bearing current remediation options,” IEEE Ind. Appl. Mag., vol. 10, no. 4, pp. 40–50, Jul./Aug. 2004.

[14] A. Muetze, Bearing Currents in Inverter-Fed AC Motors. Aachen, Germany, Shaker Verlag, 2004..

[15] A. Muetze and A. Binder, “Don’t lose your bearings—Mitigation tech­niques for bearing currents in inverter-supplied drive systems,” IEEE Ind. Appl. Mag., vol. 12, no. 4, pp. 22–31, Jul./Aug. 2006.

[16] A. Muetze and A. Binder, “Calculation of motor capacitances for pre­diction of discharge bearing currents in machines of inverter-based drive systems,” in Proc. 5th IEEE Int. Electric Mach. Drives Conf. (IEMDC), San Antonio, TX, May, 15–18, 2005, pp. 264–270.

[17] A. E. Seaver, “An equation for charge decay valid in both conductors and insulators,” in Proc. Electrostat. Soc. Amer. Inst. Electrostat.-Jpn. (ESA-IEJ) Joint Meeting, Chicago, IL, June 2002, pp. 349–360.

[18] M. D. Bryant, “Tribology issues in electric contacts,” Lecture Notes ME 383S. Austin, TX: Lubrication, Wear and Bearing Technology, Univ. of Texas at Austin, 2006.

[19] F. Paschen, “On sparking over in air, hydrogen, carbon dioxide under the potentials corresponding to various pressures,” Wiedemann Ann. Phys. Chem., vol. 37, pp. 69–96, 1889.

[20] J. M. Meek and J. D. Craggs, Electrical Breakdown of Gases. New York: Wiley, 1978.

[21] H. Raether, Electron Avalanches and Breakdown in Gases. London,, U.K.: Butterworth, 1964.

[22] I. Gallimberti, “The mechanism of the long spark formation,” J. Phys., vol. 40 no. C7, pp. 193–250, Jul. 1979.

[23] E. M. Bazelyan and Y. P. Raizer, Spark Discharge. Boca Raton, FL: CRC Press, 1997.

[24] A. Wallash, “Electric breakdown and ESD phenomena for devices with nanometer-to-micron gaps,” in Proc. Int. Soc. Opt. Eng., Conf. Rel., Testing, Charact. MEMS/MOEMS II, vol. 4980, no. 16, pp. 87–98, Jan. 2003.

[25] R. M. Schaffert, Electrophotography. New York: Wiley, 1975.

[26] A. Wallash and T. Hughbanks, “Capacitive coupling effects in spark gap devices,” in Proc. 16th Electr. Overstress Discharge (EOS/ESD) Symp., EOS/ESD Assoc., pp. 273–278, 1994.

[27] R. H. Fowler and L. Nordheim, “Elecron emission in intense electric .elds,” in Proc. Royal Soc. London, Ser. A, Containing Pap. Math. Phys. Charact., vol. 119, no. 781, pp. 173–181, May 1928.

[28] T. E. Stern, B. S. Gossling, and R. H. Fowler, “Further studies in the emission of electrons from cold metals,” in Proc. Royal Soc. London, Ser. A, Containing Pap. Math. Phys. Charact., vol. 124, no. 795, pp. 699–723, Jul. 1929.

[29] F. Gomer, Field Emission and Field Ionization. Cambridge, MA: Har­vard Univ. Press, 1961.

[30] C. A. Spindt, I. Brodie, L. Humphrey, and E. R. Westerberg, “Physical properties of thin-.lm .eld emission cathodes with molybdenum cones,”

J. Appl. Phys., vol. 47, no. 12, pp. 5248–5263, Dec. 1976.

[31] P. G. Slade and E. D. Taylor, “Electrical breakdown in atmospheric air between closely spaced (0.2 µm–40 µm) electrical contacts,” IEEE Trans. Compon. Packag. Technol., vol. 25, no. 3, pp. 390–396, Sep. 2002.

[32] A. Wallash and L. Levit. (Jan. 2003), “Electrical breakdown and ESD phenomena for devices with nanometer-to-micron gaps” in presentation at Int. Soc. Opt. Eng., Conf. Rel., Testing, Charact. MEMS/MOEMS [Online]. Available: http://www.wallash.com/allpubs.htm.

[33] R. T. Lee, H. H. Chung, and Y. C. Chiou, “Arc erosion of silver electric contacts in a single arc discharge across a static gap,” in Proc. IEE Sci., Meas. Technol., vol. 148, no. 1, pp. 8–14, Jan. 2001.

[34] J. M. Torres and R. S. Dhariwal, “Electrical .eld breakdown at microme­tre separations,” Nanotechnology, vol. 10, no. 1, pp. 102–107, Mar. 1999.

[35] Guide to the Selection of The Surface Finish of Stainless Steel on Fab­ricated Items, Solids Handling Process. Assoc. (SHAPA) Tech. Bull., 1, Jan. 2000.

Annette Muetze (S’03–M’04) received the Dipl.-Ing. degree in electrical engineering from Darmstadt University of Technology, Darmstadt, Germany and the degree in general engineering from the Ecole Cen­trale de Lyon, Ecully, France, both in 1999, and the Dr. Tech. degree in electrical engineering from Darm­stadt University of Technology in 2004.

During 2004, she was an Assistant Professor at the Electrical and Computer Engineering Department, University of Wisconsin-Madison, Madison. Since January 2007, she has been a Lecturer in the School of Engineering, University of Warwick, Coventry, UK.

Dr. Muetze was the recipient of the FAG Innovation Award 2004 for her work on inverter-induced bearing currents. She was also the recipient of the National Science Foundation CAREER Award in 2005.

H. William Oh (M’03) received the B.Sc. degree from Pusan National University, Pusan, Korea, in 1982, and the M.Sc. degree from Korea Advanced Institute of Science and Technology, Seoul, Korea, 1984, both in mechanical engineering.

From 1985 to 1988, he was with the University of Massachusetts, Amherst. He is currently the General Manager of Electro Static Technology, a division of Illinois Tool Works (ITW), Mechanic Falls, ME. He is the inventor of the AEGIS SGR Shaft Grounding Ring manufactured by Electro Static Technology. He

has extensive design and application experience in rotating shaft grounding and sliding electrical contacts, specializing in the mitigation of unwanted electrical currents. He is the holder of eight patents.

Mr. Oh is a member of the Illinois Tool Works Patent Society.

If you liked this, please tell us:
  • Facebook
  • Twitter
  • email
  • Print
  • Add to favorites
  • Google Bookmarks
  • RSS